Can a Bus & Tag device be connected via Prizm to a remote location 100km away?
An Optica ESBT B/T interface module is required to convert ESCON to B/T, and when used in conjunction with a Prizm, will support connectivity of a B/T device to a FICON channel, either locally or remotely. Currently ESBT only supports block mode Bus & Tag devices. Byte mode devices are not currently supported.